Automatic Endoscope Reprocessor

  • Commodity name: Automatic Endoscope Reprocessor
  • Commodity ID: 1215224131545092096

Product Classification:

Key words:

General hospitals due to the large number of patients, Patient endoscopy was too frequent, insufficient time for cleaning and disinfection, Disinfection is not thorough, There are serious patient hospital infection and the risk of pathogenic infection in medical staff, Although the endoscopic cleaning and disinfection device used in the hospital can save manpower and control time, However, full automation and specification requirements have not been met, The Automatic Endoscope Reprocessor is developed by our company is controlled by a microcomputer, one-button start, high-pressure rotate arm spray, automatic leakage testing, cleaning, enzyme washing, rinsing, disinfection, final washing, alcohol dry or air dry, printing, Full immersion of the mirror body, Complete the washing process in only 8 - 15 minutes, highly improved the utilization rate of hospital endoscopic turnover, reduced the queuing and waiting time for patients, The ISO 15883-4 version meets the international standards of endoscopic cleaning and disinfection machine (Automatic Endoscope Reprocessor standard). Convenient, fast, scientific and efficient, no damage to endoscopy, and protect the health of medical staff, reduce the labor intensity of medical staff.


Immediate consultation
+
  • undefined

Product Details


 

  General hospitals due to the large number of patients, Patient endoscopy was too frequent, insufficient time for cleaning and disinfection, Disinfection is not thorough, There are serious patient hospital infection and the risk of pathogenic infection in medical staff, Although the endoscopic cleaning and disinfection device used in the hospital can save manpower and control time, However, full automation and specification requirements have not been met, The Automatic Endoscope Reprocessor is developed by our company is controlled by a microcomputer, one-button start, high-pressure rotate arm spray, automatic leakage testing, cleaning, enzyme washing, rinsing, disinfection, final washing, alcohol dry or air dry, printing, Full immersion of the mirror body, Complete the washing process in only 8 - 15 minutes, highly improved the utilization rate of hospital endoscopic turnover, reduced the queuing and waiting time for patients, The ISO 15883-4 version meets the international standards of endoscopic cleaning and disinfection machine (Automatic Endoscope Reprocessor standard). Convenient, fast, scientific and efficient, no damage to endoscopy, and protect the health of medical staff, reduce the labor intensity of medical staff.

 

  Wide range of application: full immersion, cleaning, disinfection and other flexible endoscopy including gastroscopy, colonoscopy, bronchoscopy, ear, nose and laryngoscopy, cholandoscopy and etc
  High washing efficiency: In order to improve the endoscopic circulation efficiency, the fastest cleaning speed can be ≤ 22 minutes / flexible endoscope
  Guarantee of cleaning effect::cleaning standard according to WS 507-2016 Technical Specification for WS 507-2016 Flexible Endoscopic Cleaning and Disinfection
  Automatic cleaning process: one process completes all the necessary cleaning steps, the leakage during the whole processing
  Standard with intelligent traceability: closed-loop data record

 

  Working processing

 

 

  Technical parameters

 

 

  Characters of Luxury CV-AER90:

  leakage testing function
  Endoscopic leakage detection is completed before contact with the liquid in the endoscopic cleaning and disinfection. If the endoscopic leakage value exceeds the pre-set allowable leakage value, the visual and acoustic alarm signal is issued and the program operation is automatically terminated.

Endoscopic lumen was perfusion washed
  Endoscopic lumen, washed and gas, injection, biopsy, sucked of lumens, circulating perfusion washing, to eliminate the formation of bacterial biofilm.
  All-round, full pipeline cleaning and disinfection
  The washing tank is equipped with a rotating nozzle and a rotating spray arm to comprehensively clean and thoroughly disinfect the external surface of the endoscope, and the circulating water flow continues to continuously clean and disinfect all the internal channels of the endoscope.
  Self-disinfection function
  After equipment maintenance or interruption, independent self-disinfection procedures can be run. The own disinfection function can thoroughly disinfect the channels and pipes including 0.2μm filter, to avoid the cleaning and disinfectant becoming a pollution source.
  Sterile water rinsing
  After disinfection, it were rinsed using sterile water from a 0.2 μm filter to avoid unclean rinsing water again contaminating the sterilized endoscopy. Drying
  Alcohol or sterile air drying are optional

  Automatic foot door switch
  Visualize automatic toughened glass doors to facilitate cleaning and disinfection; foot switch and manual touch screen automatically complete opening and closing, to avoid cross-infection caused by endoscopy after contacting the machine by hand, which meets the requirements of hospital infection.
  Fully enclosed
  The cleaning tank adopts a fully closed structure, automatically toughened glass door to press the sealing glue strip to prevent the leakage of disinfectant odor andmaximize the health of the operator.
  Automatic chemical aids were added
  During the washing process, automatic measurement to add chemical additives, such as enzymes, alcohol and disinfectant, insufficient dose machine full fault alarm, display the fault content and prompt the solution.
  Automatic dosing of disinfectant
  Provide automatic dosing device to monitor disinfectant concentration and protect the safety of operators.
  The disinfectant has an automatic dosing and discharge function
  It has the function of automatic dosing and discharge of disinfectant. When dosing disinfectant, only pour the disinfectant into the disinfection tank, start the disinfectant dosing program, and start the discharge program when need to be discharged

 

 